JKLHYJ-0.6/1KV Aerial Insulated Cable
QIFAN JKLHYJ-0.6/1KV Aerial Insulated Cable is a high quality cable product for low voltage power transmission. It adopts high-quality copper core and Aerial insulated material to ensure the high efficiency and reliability of power transmission.
The rated voltage of this cable is 0.6/1KV , suitable for various low voltage application scenarios. For example, it can be used in home circuits, building circuits, lighting systems, etc.
The cable uses Aerial insulated, which has good chemical and abrasion resistance. This allows it to be used in a variety of harsh environments such as wet, corrosive or high temperature environments
In addition, the cable complies with international standards and safety standards, and has a long service life and good safety performance. It has been rigorously tested and inspected to ensure its quality and reliability.
Advantages of JKLHYJ-0.6/1KV Aerial Insulated Cable
The wire uses high-quality polyvinyl chloride (Aerial) as the insulation material, which has good heat resistance. It can work at higher temperature without melting or deforming the insulating material, ensuring the safety and reliability of the wire.
Aerial material has excellent corrosion resistance and can resist the erosion of many chemical substances, including acids, alkalis and solvents. This makes it suitable for use in a variety of environmental conditions, including wet, acidic or alkaline environments.
The wire has good electrical properties, providing stable current transmission and low resistance. It has low resistance and inductance, which can reduce energy loss and signal attenuation, ensuring the efficiency and quality of power transmission.
The wire is flexible and bendable for easy installation and routing. Its skin is smooth, not easily damaged, and has good wear resistance. This allows installers to quickly and easily complete the routing and connection of wires, improving work efficiency.
Technical Specifications
Basic Introduction of JKLHYJ-0.6/1KV Aerial Insulated Cable
Model: | JKLHYJ-0.6/1KV |
Rated Voltage: | 300/500V |
Conductor: | Type 1 copper conductors for solid conductors; Type 2 copper conductors for stranded conductors. |
Insulation: | PVC |
Product Standards: | GB/T 5023-2008 |
Specification Range: | 0.5~1.0 mm^2 |
Conductor Maximum Operating Temperature: | +70°C |
Operating Environment Temperature: | -15°C~+40°C |
Cable Laying Temperature: | ≥ 0°C |
Minimum Bending Radius: | 6D (D is the actual outer diameter of the cable) |
Laying method: | Surface laying, pipe laying, trunking laying, etc. |
Scope of Application: | This product is suitable for electrical appliances, instruments and meters and power lighting with AC rated voltage of 300/500V and below |
1KV Aerial Insulated Cable Series
Model | Name | Main usage | ||||
JKV-0.6/1KV | Copper-Core Pvc Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKLV-0.6/1KV | Aluminum-Core Pvc Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKLHV-0.6/1KV | Aluminum Alloy Core Pvc Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKY-0.6/1KV | Copper-Core Pe Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKLY-0.6/1KV | Aluminum-Core Pe Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKLHY-0.6/1KV | Aluminum Alloy Core Pe Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKYJ-0.6/1KV | Copper-Core Yjv Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKLYJ-0.6/1KV | Aluminum-Core Yjv Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
JKLHYJ-0.6/1KV | Aluminum Alloy Core Yjv Insulated Aerial Cable of Rated Voltage 0.6/1Kv | Overhead fix-ed layoutandwireconducting.etc. | ||||
—END— |
JKLHYJ-0.6/1KV General Data
Norminal section ( mm² ) | Min. wire No. Of conductor | Outer dia. ( reference ) mm | Insulation thickness mm | Average dia. Of single core mm | Conductor resistance at 20°C ( Q/km ) | Min. insulation resistance in rated operation temperature | ||||
Hard copper | Soft copper | AI conductor | Al alloy | 70℃ | 90℃ | |||||
10 | 6 | 3.8 | 1.0 | 6.5 | 1.906 | 1.830 | 3.080 | 3.574 | 0.0067 | 0.67 |
16 | 6 | 4.8 | 1.2 | 8.0 | 1.198 | 1.150 | 1.910 | 2.217 | 0.0065 | 0.65 |
25 | 6 | 6.0 | 1.2 | 9.4 | 0.749 | 0.727 | 1.200 | 1.939 | 0.0054 | 0.54 |
35 | 6 | 7.0 | 1.4 | 11.0 | 0.540 | 0.524 | 0.868 | 1.007 | 0.0054 | 0.54 |
50 | 6 | 8.4 | 1.4 | 12.3 | 0.399 | 0.387 | 0.641 | 0.744 | 0.0046 | 0.46 |
70 | 12 | 10.0 | 1.4 | 14.1 | 0.276 | 0.268 | 0.443 | 0.514 | 0.0040 | 0.40 |
95 | 15 | 11.6 | 1.6 | 16.5 | 0.199 | 0.193 | 0.320 | 0.371 | 0.0039 | 0.39 |
120 | 18 | 13.0 | 1.6 | 18.1 | 0.158 | 0.153 | 0.253 | 0.294 | 0.0035 | 0.35 |
150 | 18 | 14.6 | 1.8 | 20.2 | 0.128 | – | 0.206 | 0.239 | 0.0035 | 0.35 |
185 | 30 | 16.2 | 2.0 | 22.5 | 0.1021 | – | 0.164 | 0.190 | 0.0035 | 0.35 |
240 | 34 | 18.4 | 2.2 | 25.6 | 0.0777 | – | 0.125 | 0.145 | 0.0034 | 0.34 |
—END— |
Tags: Aerial Insulated Cable | JKLHYJ-0.6/1KV